Enable continuous monitoring on analog input

Note The Connect Tank firmware must be upgraded before continuous monitoring can be enabled on the analog or digital input. For information, see Configure the Continuous Monitoring feature.

  1. Follow the standard process to configure an Analog 4-20mA Current Loop or Analog Voltage Input. For instructions, see Enable and configure analog inputs.
  2. The analog input must be enabled. Verify that the Interface Enable (ena) option is set to On.
  3. Verify that the Continuous Monitoring Enable (mon) option is set to On.
  4. Click Save.
  5. Apply the configuration changes:
    1. Click Save > Schedule. The Save Device Properties dialog appears.
    2. Select Immediate.
    3. Select Schedule Offline.
    1. Click Schedule. Connect Tank downloads and applies configuration changes the next time it connects to Remote Manager.
  6. Configure the buffer time for the sensor to ensure the desired amount of data is stored when an alarm occurs. For information, see Configure the buffer time for continuous monitoring.