Configure the wake up interval for a Connect Sensor

You can configure a schedule for a device that determines the first wake-up time, the time interval between reading the sensor connected to the Connect Sensor, and how many reads should occur before data is pushed from the device to Digi Axess.

By default, the Connect Sensor is configured to wake up and connect to Digi Axess every 12 hours. If you configure a schedule, you can revert the configuration to the default, if needed.

  1. Access the web UI for Connect Sensor from the Device Summary page. The Automation Dashboard displays.

  2. Choose Services > Digi Axess Services > Device Schedule.

  3. Click Edit to allow changes to be made to the page.

  4. Configure the configuration synchronization schedule.

    1. In the First Report field, enter the first time that the Connect Sensor should wake up, connect to Digi Axess, push sensor data, and receive data pushed from Digi Axess.

    2. In the Read Interval fields, enter the time interval between reads (data collection) from the sensors.

    3. In the Report Interval field, enter the number of reads that should occur before Connect Sensor pushes data to Digi Axess.

  5. Click Update to save your changes. A confirmation dialog displays.

  6. Click OK to complete the change.