Review status information for a Connect Sensor

The device status, network status, and configuration information for a Connect Sensor can be displayed in the Device Summary page.

Automation Control Groups

Any automation control groups that have been assigned a group name display as a section on this page. The groups are unique to each Connect Sensor.

As an alternative, you can also review automation control group data in the Automation Dashboard page.

Device Status

The device status information is calculated for the current data as of the last time that the device reported information.

Item Description

Battery 1 Status

Battery 2 Status

A battery graphic describes the status of the battery.

  • Full green: Battery status good.

  • Partial green: Battery status good.

  • Yellow: Battery should be changed soon.

  • Red: Battery needs to be changed.

  • Dash: Battery is not plugged in.

External Voltage

The voltage of a physically connected power supply.

Battery Only Connection Count

The number of connections made by the device without an external voltage connected. The external voltage is counted only if it is 9v or greater.

Case Temperature

The temperature of the Connect Sensor enclosure.

CPU Temperature

The temperature of the Connect Sensor device.

Firmware Version

The current firmware version installed on the device.

Network Status

Item Description

APN

The APN assigned to the device.

  • (Auto): The APN is not yet known. This may occur if the Connect Sensor has not yet connected to Digi Axess.

  • <APN number>: The actual APN string that was used during the most recent connection between Connect Sensor and Digi Axess, or the APN that was manually assigned in the web UI.

Mobile Version

Displays the version number of the Digi application used to interact with the modem.

Cell Modem Model

Name of the cell modem model in the device.

Cell Modem Firmware

The current version of the cell modem firmware.

Provider

The name of the cellular carrier.

ICCID

The SIM card identifier.

IMSI

The unique International Mobile Subscriber Indentity assigned to the SIM card.

RSSI (Avg/Low/High)

The average, low, and high signal strength for the selected date.

EC/IO (Avg./Low/High)

The average, low, and high measure of the quality of the signal from the tower to the cell modem.

Cell ID

The unique number by a cell tower can be identified within a location area code (LAC) or a GSM network.

Last Disconnect Reason

The reason for the last time the device disconnected from a cell tower.

Config Status

Item Description

Running Device Config

The name of the saved configuration that is currently applied on the device.

Sync Status

Information about the next synchronization between Digi Axess and the device. Options are:

  • Synced

  • Scheduled - Partial Sync

  • Scheduled - Full Sync

Last Sync

The date and time of the last full configuration synchronization between Digi Axess and the device.