Manually wake the Connect Sensor XRT-M NEMA
The Connect Sensor XRT-M NEMA is in sleep mode until it wakes to connect to Digi Axess at a scheduled time. You can wake the device manually, if needed, using the magnet supplied with the device. Waking the Connect Sensor XRT-M NEMA manually forces a connection to Digi Axess.
-
You must physically be near enough to the Connect Sensor XRT-M NEMA to touch it.
-
Locate the magnet sensor sticker on the side of the device.
-
Swipe a magnet across the magnet sensor sticker to wake the Connect Sensor XRT-M NEMA.
-
The LED on the edge of the SIM card slot shows the status of the device. Refer to the LED wake sequence in the table below.
-
The Connect Sensor XRT-M NEMA connects to Digi Axess when it successfully connects to the cellular network.
LED wake sequence
The LED on the edge of the SIM card slot shows the status of the device. When the device wakes, the device connects to Digi Axess and pushes any collected data, and collects any configuration changes that are pushed from Digi Axess. This process make take a few minutes.
Behavior | LED indication |
---|---|
Wake by user (as by magnet) | Red & Blue on together for 1 sec |
While sensors are being sampled | Blue LED flashes (2Hz), generally on for a very short period |
Cell initialized, trying to connect | Green LED flashes (2Hz) |
Cell has connection | Green LED on solid |
Cell completes with success | Blue LED on solid 3 sec |
Cell completes with failure | Red LED on solid 3 sec |
During firmware update | Toggle quickly between Red and Blue LED |