ATEX Directive compliance

IMPORTANT This information applies only to the following variants:

Digi complies with ATEX directives to ensure a safe working environment when working with equipment in potentially explosive atmospheres. The IX30 device is compliant to the ATEX Directive under Certification UL 22 ATEX 2585X.

Special conditions for safe user

The equipment shall be used only in an area of not more that pollution degree 2, as defined in EN/IEC 60664-1.

The equipment shall be installed in an enclosure that provides a degree of protection not less than IP 54 in accordance with EN/IEC 60079-0 and only accessible by the use of a tool.

Transient protection shall be provided that is set at a level not exceeding 140% of the peak rated voltage value at the supply terminals to the equipment.

English warnings

WARNING! Use 24-12 AWG 2-3-3- mm2 wire with a minimum temperature rating of 80º C (recommended 105º C) for connecting to terminal blocks. Torque all screws from 5 to 8 inches per pound.

WARNING! When connecting to the optional earth ground provided, use an insulated ring terminal for the #6 screw, and torque from 4.5 to 5 inches per pound.

WARNING! HOT PARTS! To avoid burns, switch off the device and wait at least one hour before handling device parts.

French warnings

WARNING! Pour le raccordement aux borniers, utilisez un fil de calibre 24-12 AWG (2,3,3mm² ) avec une température nominale minimale de 80°C (105°C recommandé). Serrez toutes les vis à un couple de 5 à 8 pouces par livre.

WARNING! Lors de la connexion à la terre en option fournie, utilisez une cosse à anneau isolée pour la vis n° 6 et serrez à un couple de 4,5 à 5 pouces par livre.

WARNING! PIÈCES CHAUDES! Pour éviter les brûlures, éteignez l'appareil et attendez au moins une heure avant demanipuler les pièces de l'appareil.

ATEX/UKEX standards

ATEX Directive No. 2014/34/EU under Certification UL 22 ATEX 2585X

UK Statutory Instrument 2016 No. 1107 under Certification UL22UKEX2668X [Applicable only for IX30-00G4]

IECEx standards