D7 (DIO7/CTS Configuration)
This command applies to the XBee 3 DigiMesh RF Module.
Sets or displays the DIO7/CTS configuration (Micro pin 24/SMT pin 25/TH pin 12).
Parameter range
0, 1, 3 - 7
Parameter | Description |
---|---|
0 | Disabled |
1 |
CTS flow control |
2 | N/A |
3 | Digital input |
4 | Digital output, low |
5 | Digital output, high |
6 | RS-485 enable, low |
7 | RS-485 enable, high |
Default
1