V+ (Supply Voltage Threshold)

This command applies to the XBee 3 Zigbee RF Module.

Define the supply voltage threshold that appends the supply voltage to outgoing I/O sample frames.

If the measured supply voltage falls below or equal to this threshold, the supply voltage will be appended to outgoing I/O sample frames and set bit 7 of the Analog Channel Mask.

Set V+ to 0 to not include the supply voltage.

Set V+ to 1 to always include the supply voltage.

Example

To include a measurement of the supply voltage when it falls below 2.7 V, set V+ to 2700 = 0xA8A.

Parameter range

0 - 0xFFFF (in mV)

Default

0