ET (End Device Timeout)
This command applies to the XBee 3 Zigbee RF Module.
Sets the child table parent timeout. This command is set conditionally on an XBee3 parent or sleepy end devices as follows:
-
On an all XBee3 network, set ET command only on the sleepy end device. The sleepy end device sends the timeout to the parent when joining the network.
-
On a mixed network where the parent is an XBee3 and the sleepy end device is S2B/S2C, set the ET command only on the parent module, which will be used for the child table timeout.
Parameter range
0 - 14
Parameter | Child table timeout |
---|---|
0 | 10 seconds |
1 | 2 minutes |
2 | 4 minutes |
3 | 8 minutes |
4 | 16 minutes |
5 | 32 minutes |
6 | 64 minutes |
7 | 128 minutes |
8 | 256 minutes |
9 | 512 minutes |
10 | 1024 minutes |
11 | 2048 minutes |
12 | 4096 minutes |
13 | 8192 minutes |
14 | 16384 minutes |
Default
1 (2 minutes)