This command applies to the XBee 3 Zigbee RF Module.
Sets or displays the Command mode timeout parameter. If the local device enters Command mode and does not receive any valid AT commands within this time period, Command mode silently exits.
Parameter range
2 - 0x28F
Default
0x64 (10 seconds)