Missing DIA channel datapoint alarm

This alarm fires when devices have not reported DIA channel data within a specified time interval.

From the Alarm Type drop-down in the Add Alarm dialog, select the Missing DIA Channel DataPoint option for these fields to appear in the dialog.

The Fire Condition section contains the conditions that must be met for the alarm to fire.

Field Description
Dia instance Select the DIA instance from the options in the drop-down list. To set the alarm to fire on all DIA instances, select *.
Channel Select the DIA channel from the options in the drop-down list. To set the alarm to fire on all DIA channels, select *.
Upload interval Specify the time interval between datapoint uploads to the server. The default is 1 hour.
Reading interval Specify the time interval between reported datapoints from the device. The default is 10 minutes.
Reset Condition

Determines whether the alarm should be automatically reset after data has been reported. Options are:

  • Selected: The alarm is automatically reset.
  • Deselected: The alarm is not automatically reset. You must manually reset this alarm. See Reset an alarm.

Click Next to specify the scope for the alarm.

Field Description
Scope

Specify the devices that should be monitored for this alarm. Options are:

  • Group: Select the Group option and then select a device group. All of the devices in that group are monitored. Only one group can be selected.
  • Device: Select the Device option to display a list of all of the devices registered in OEM Cloud. Click the device that you want to monitor. Only one device can be selected.

 