RB (Packetization Threshold)
This command applies to the XTC RF Module.
Sets or displays the character threshold value.
RF transmission begins after a device receives data in the DIN buffer and meets either of the following criteria:
- The UART receives RB characters
- The UART receive lines detect RO character times of silence after receiving at least 1 byte of data
If a device lowers PK below the value of RB, RB is automatically lowered to match the PK value.
If RO = 0, the device must receive RB bytes before beginning transmission.
RB and RO criteria only apply to the first packet of a multi-packet transmission. If data remains in the DIN buffer after the first packet, transmissions continue in a streaming manner until there is no data left in the DIN buffer.
Binary command
0x20 (32 decimal)
Parameter range
0 - PK parameter value
(up to 0x800 bytes)
Default
0x800 (2048 bytes)
Bytes returned
2