FT (Flow Control Threshold)

This command applies to the XTC RF Module.

Sets or displays the flow control threshold.

De-assert CTS when the number of bytes specified by the FT parameter are in the DIN buffer. Re-assert CTS when less than FT - 16 bytes are in the UART receive buffer.

Binary command

0x24 (36 decimal)

Parameter range

0x11 - 0xC00 [bytes]

Default

0xBBF (DI buffer size minus 0x11)

Bytes returned

2