CF (Number Base)

This command applies to the XTC RF Module.

Sets or displays the command formatting setting.

The firmware always enters and reads the following commands in hex, no matter what the CF setting is:

VR (Firmware Version)

HV (Hardware Version)

KY (AES Encryption Key)

Binary command

N/A

Command type

Command mode options

Parameter range

0 - 2

Parameter Configuration
0 Commands use the default number base; decimal commands may output units.
1 All commands are forced to unsigned, unit-less hex.
2 Commands use their default number base; no units are output.

Default

1

Bytes returned

1