Enable and configure a serial power output
This section describes how to configure serial power. Note that powering sensors reduces battery life; to reduce unnecessary battery consumption, only wake the device when needed.
Note The serial power output option can be used only with a Modbus device.
If Connect Tank is providing power to the Modbus device, you must enable the serial power output.
To set serial power output options in Remote Manager:
- Sign in to Remote Manager.
- Click the arrow next to your user name and choose Open Classic Remote Manager.
- Click Device Management > Devices tab.
- Double-click the Connect Tank device you want to configure.
- Expand the Configuration menu.
- Select Serial: Power Output.
- Enable the output by selecting On for Power Output Enable.
- Select the appropriate voltage Output Level for your power output. Refer to the manufacturer specifications for the sensor.
- Enter the appropriate Read Delay that your sensor needs to stabilize before reading the sensor input value. Refer to the manufacturer specifications for the sensor. For example, a sensor may need 7 seconds to power on and stabilize before it can get an accurate reading.
- Apply the configuration changes:
- Click Save > Schedule. The Save Device Properties dialog appears.
- Select Immediate.
- Select Schedule Offline.
- Click Schedule. Connect Tank downloads and applies configuration changes the next time it connects to Remote Manager.
Note A higher read delay keeps the device powered on longer, which reduces battery life.