Internal Temperature option definitions

The following table provides Remote Manager internal temperature monitoring options for Connect Tank. For additional information about using these options, see Configure internal temperature settings.

CAUTION! If Connect Tank sends reports less than 15 minutes apart, it may result in an internal temperature that is above the ambient temperature.

Option Description

Range

Default
Interface Enable Enables or disables the internal temperature sensor. On/Off Off
High Alarm Enables or disables high alarm reports for the internal temperature value. On/Off Off
High Threshold Specifies the internal temperature in degrees Celsius that generates a high alarm report when High Alarm is On. -100 to 100 50.0
Low Alarm Enables or disables low alarm reports for the internal temperature value. On/Off Off
Low Threshold Specifies the internal temperature in degrees Celsius that generates a low alarm report when Low Alarm is On. -100 to 100 0
Hysteresis

Specifies the degrees in Celsius to keep an alarm on or shut off an alarm during high and low alarm states.

0 — Hysteresis is off

1 or more — Hysteresis is on and managing alarms

0 to 100 5.0