Digital Input option definitions
The following table provides Remote Manager definitions for Connect Tank Digital: Input options. For details about setting these options, see Enable and configure a digital input.
Option | Description |
Range |
Default |
---|---|---|---|
Interface Enable | Enables or disables the digital input source. | On/Off | Off |
High Alarm |
Enables or disables high alarm reports for the digital input source. When enabled, sends an alarm report when the pin is high. |
On/Off | Off |
Low Alarm | Enables or disables low alarm reports for the digital input source. When enabled, sends an alarm report when the pin is low. | On/Off | Off |
Delta Low Alarm | Enables or disables delta low alarm reports for the digital input source. When enabled, sends an alarm report for a falling transition. | On/Off | Off |
Delta High Alarm | Enables or disables delta high alarm reports for the digital input source. When enabled, sends an alarm report for a rising transition. | On/Off | Off |
Rising Edge Wake |
Enables or disables the device to monitor a digital input during sleep mode. When enabled, wakes the device when the digital input changes from low voltage to high voltage (rising edge) and reports the value to Remote Manager with the other sensor and device data. |
On/Off | Off |
Falling Edge Wake |
Enables or disables the device to monitor a digital input during sleep mode. When enabled, wakes the device when the digital input changes from high voltage to low voltage (falling edge) and reports the value to Remote Manager with the other sensor and device data. |
On/Off | Off |
Enable pullup | Enables or disables the internal pull-up resistor to drive a logic level voltage. For example, use this to drive a logic voltage across a mechanical switch to read the value (open or closed) of the mechanical switch. | On/Off | Off |
Sensor description | Specifies description of the sensor for this input source. | Text | Empty |