BD (UART Baud Rate)
This command applies to the XBee 3 DigiMesh RF Module.
This command configures the serial interface baud rate for communication between the UART port of the device and the host.
The device interprets any value between 0x12C and 0x0EC400 as a custom baud rate. Custom baud rates are not guaranteed and the device attempts to find the closest achievable baud rate. After setting a non-standard baud rate, query BD to find the actual operating baud rate before applying changes.
Parameter range
Standard baud rates: 0x0 - 0x0A
Non-standard baud rates: 0x12C - 0x0EC400
Parameter | Description |
---|---|
0x0 | 1200 b/s |
0x1 | 2400 b/s |
0x2 | 4800 b/s |
0x3 | 9600 b/s |
0x4 | 19200 b/s |
0x5 | 38400 b/s |
0x6 | 57600 b/s |
0x7 | 115200 b/s |
0x8 | 230,400 b/s |
0x9 | 460,800 b/s |
0xA | 921,600 b/s |
Default
0x03 (9600 baud)