Set XLR radio IP socket (Ethernet) options

To set XLR radio IP socket (Ethernet) configuration options:

  1. From the XLR PRO Configuration and Management page, select XLR Radio IP Socket Configuration. The Socket Radio Configuration page appears.
  1. Enable or disable IP socket mode:
    • To enable socket mode, select Enable IP Socket Mode.
    • To disable socket mode, deselect Enable Socket Mode.
  2. If socket mode is enabled, enter the following:
    • Protocol: Select UDP or TCP.
    • Baud Rate: Enter the baud rate for socket mode, from 2400 through 460800. The default is 460800.
    • Destination IP Address: Enter the destination IP address in IPv4 format. This address is only used when traffic is initiated from the XLR PRO. When traffic is initiated from the Ethernet interface, the Destination IP address is the address of the external device.
    • Local Port: Enter the local listening port. The default is 9750.
    • Remote Port: Enter the remote listening port. The default is 9750.
    • TCP Client Timeout: Enter the number of seconds the client waits without any traffic before closing the connection. The default is 60 seconds.
    • TCP Server Timeout: Enter the number of seconds the server waits without traffic before closing the connection. The default is 60 seconds.
  3. Click Apply.

 