P0 (DIO10/RSSI/PWM0 Configuration)

This command applies to the XBee/XBee-PRO S2C DigiMesh 2.4.

Sets or displays the RSSI/PWM0 configuration (TH pin 6/SMT pin 7).

When configured as a PWM output, you can use M0 to set the PWM duty cycle.

Parameter range

0 - 5

Parameter Description
0 Disabled
1 RSSI PWM output
2

PWM0 output. Value is controlled by M0 parameter or by I/O line passing.

3 Digital input
4 Digital output, low
5 Digital output, high

Default

1