DB (Last Packet RSSI)
This command applies to the XBee/XBee-PRO SX RF Module.
Reports the RSSI in -dBm of the last received RF data packet. DB returns a hexadecimal value for the -dBm measurement.
For example, if DB returns 0x60, then the RSSI of the last packet received was -96 dBm.
The RSSI measurement is accurate within ±2 dB from approximately -50 dBm down to sensitivity.
DB only indicates the signal strength of the last hop. It does not provide an accurate quality measurement for a multihop link.
If the XBee/XBee-PRO SX RF Module has been reset and has not yet received a packet, DB reports 0.
This value is volatile—the value does not persist in the device's memory after a power-up sequence.
Parameter range
0x28 - 0x6E (-40 dBm to -110 dBm) [read-only]